Part Datasheet Search > Signal Relays > Schneider Electric > LP1K0910BD Datasheet PDF > LP1K0910BD Datasheet Pages 30/56
LP1K0910BD
Price from AiPCBA
LP1K0910BDDatasheet PDF
Page:
of 56 Go
If the format of the manual is confusing, please download and read the original PDF file.
www.schneider-electric.us
18
IEC CONTACTORS AND
STARTERS
18-30
© 2009 Schneider Electric
All Rights Reserved
Accessories TeSys
®
U Simple Motor Starter
Refer to Catalog 8502CT0201
Table 18.113: Line Phase Barrier (optional)
a
Description
Catalog
Number
$ Price
For use as a self protected combination starter, UL508E, incoming line phase barrier must be used. LU9SP0 15.00
a See page 18-29 for placement on the power base.
Table 18.114: Reverser b
Control
Connection
Max. Current
(Amps)
Three Phase
(HP max.)
Self-Protected
Starter Base
200/208 V 220/240 V 460 V 575 V
Catalog
Number
$ Price
With screw terminations
12 3 3 7.5 10 LU2B12c 488.00
32 10 10 20 25 LU2B32c 720.00
b See page 18-29 for placement on the power base.
c Voltage code required.
Select Control Unit Optionsef
Setting Range
(Amps)
Standard
3-phase
Class 10 trip d
$ Price
Advanced
3-phase
Class 10 trip d
$ Price
Advanced
single-phase
Class 10 trip d
$ Price
Advanced
3-phase
Class 20 trip d
$ Price
0.15–0.6 LUCAX6•• 120.00 LUCBX6•• 150.00 LUCCX6•• 150.00 LUCDX6•• 150.00
0.3–1.4 LUCA1X•• 120.00 LUCB1X•• 150.00 LUCC1X•• 150.00 LUCD1X•• 150.00
1.25–5.0 LUCA05
•• 120.00 LUCB05•• 150.00 LUCC05•• 150.00 LUCD05•• 150.00
3–12 LUCA12
•• 120.00 LUCB12•• 150.00 LUCC12•• 150.00 LUCD12•• 150.00
4.5–18 d LUCA18•• 120.00 LUCB18•• 150.00 LUCC18•• 150.00 LUCD18•• 150.00
8–32 d LUCA32•• 120.00 LUCB32•• 150.00 LUCC32•• 150.00 LUCD32•• 150.00
d Complete catalog number by adding appropriate code from voltage code table below. For example: LUCAX6FU.
e Control units for 4.5–18 and 8–32 can be used ONLY with 32 amp rated power bases (LUB32 / LU2B32).
f The control unit contains solid state overload relay and control power source for TeSys U.
For more details on the different control units, their functions, and placement on the power base see page 18-29.
Table 18.115: Voltage Codes
Volts 24 48–72 110–240
DC BLgb ——
AC B
DC or AC ESj FU
g Voltage code to use for a power base with a communication module.
h DC voltage with range of 0.90 to 1.10 of nominal.
i 48–72 Vdc; 48 Vac
Table 18.116: Current Limiter jk
Accessory Application Technical Data Mounting
Catalog
Number
$ Price
Current limiter/isolator
Additional current limiting aspects
for the starter
130 kA at 460 V
60 kA at 575 V
Direct mounting to LUB
and LU2B
LUALB1 171.00
Limiter cartridge Replacement cartridge for LUALB1
130 kA at 460 V
65 kA at 575 V
LUALF1 78.00
j Increases the breaking capacity of the motor starter.
k See page 18-29 for placement on the power base.
Table 18.117: Control Unit Multifunction lm
Setting Range
(Amps)
Multifunction programmable $ Price
0.15–0.6 LUCMX6BL
615.00
0.3–1.4 LUCM1XBL
1.25–5.0 LUCM05BL
3–12 LUCM12BL
4.5–18 LUCM18BL
8–32 LUCM32BL
l Offers motor management system capabilities. For more details see the LUCM on page 18-31.
m See page 18-29 for placement on the power base.
Table 18.118: Function Modules no
Module Description For use with:
Operation
Requirements
Catalog
Number
$ Price
Fault differentiation with
manual reset
(thermal overload)
Provides indication between an overload trip
and a short circuit trip.
Advanced control units only
24–250 Vac or Vdc
(power from control unit)
LUFDH20 156.00
Fault differentiation with
auto reset
LUFDA10 156.00
Thermal overload
pre-alarm
Signals when the motor current reaches 1.05
of the full load setting on the control unit.
Advanced control units only
24–250 Vac or Vdc
(power from control unit)
LUFW10 156.00
Motor load indication
Provides a signal proportional to the average
currents in the three phases divided by the full
load current setting of the control unit. The
output corresponds to a load status of 0–2
times the full load setting of the control unit.
Advanced or multi-function
control units
4–20 mA
(requires separate 24 Vdc power
supply)
LUFV2 188.00
Parallel wiring
Provides a convenient way to reduce control
wiring and allow for connecting starters to a
communications network by providing 24 Vdc
for the starters.
Advanced or multi-function
control units(24 Vdc only) and
LU9BN11C or LU9MRC pre-
wired connector
LU9G02
splitter box and PLC network
LUFC00 57.00
n Offers customization for specific application requirements.
o See page 18-29 for placement on the power base.
Line Phase Barrier
Reverser Unit assembled
under the Power Base
Current Limiter and its
Cartridge
Control Unit
Multifunction
Motor load indicator
Alarm differentiation
Parallel wiring
I11
Discount
Schedule
idth:4.800000px;height:7.140000px;background-color:rgba(255,255,255,0.000001);">

LP1K0910BD Documents

Schneider Electric
56 Pages / 5.46 MByte
Schneider Electric
16 Pages / 0.43 MByte
Schneider Electric
70 Pages / 3.42 MByte
Schneider Electric
26 Pages / 2.53 MByte

LP1K0910 Documents

Schneider Electric
TeSys K contactor - 3P, 3 NO, AC-3- 440V 9A - 24V DC coil
Schneider Electric
TeSys LP1K 3Pole Contactor, 9A, 4kW, 24V dc Coil
Schneider Electric
Schneider Electric Telemecanique - LP1K09103BD
Schneider Electric
Schneider Electric Telemecanique - LP1K0910GD
Schneider Electric
Schneider Electric Telemecanique - LP1K0910CD
Schneider Electric
Schneider Electric
Schneider Electric Telemecanique - LP1K0910UD
Schneider Electric
Schneider Electric Telemecanique - LP1K09103BD3
Schneider Electric
Schneider Electric Telemecanique - LP1K0910FD
Schneider Electric
Part Datasheet PDF Search
72,405,303 Parts Datasheet PDF, Update more than 5,000 PDF files ervery day.
Popular Datasheet