Part Datasheet Search > Signal Relays > Schneider Electric > LP1K0910BD Datasheet PDF > LP1K0910BD Datasheet Pages 31/56
LP1K0910BD
Price from AiPCBA
LP1K0910BDDatasheet PDF
Page:
of 56 Go
If the format of the manual is confusing, please download and read the original PDF file.
www.schneider-electric.us
18
IEC CONTACTORS AND
STARTERS
© 2009 Schneider Electric
All Rights Reserved
18-31
Accessories TeSys
®
U Simple Motor Starter
Refer to Catalog 8502CT0201
Configuration and Connection Accessories
\
Powerbus
Additional accessories and components are available, including:
Mounting accessories
Gateways
Cabling accessories
Magelis
®
remote display unit
For the complete line of TeSys U-Line motor starter accessories and all technical details (specifications,
wiring diagrams, etc.) pertaining to the product line, refer to Catalog 8502CT0201.
Table 18.119: Communication Modules de
Module Description For use with:
Operation
Requirements
Catalog
Number
$ Price
AS-Interface
Communication
Allows the TeSys U starter to be connected
directly to the network using AS-Interface
protocols.
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11C or LU9MRC
pre-wired connector
Requires separate 24 Vdc
power supply and AS-Interface
network
ASILUFC5 188.00
AS-Interface V2
Communication
Allows the TeSys U starter to be connected
directly to the network using AS-Interface V2
protocols.
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11C or LU9MRC
pre-wired connector
Requires separate 24 Vdc
power supply and AS-Interface
V2 network
ASILUFC51 188.00
Modbus
®
Communication
Protocol
Allows the TeSys U starter to be connected
directly to the network using
Modbus protocols.
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11C or LU9MRC
pre-wired connector
Requires separate 24 Vdc
power supply
LULC033 218.00
Advantys™ STB
Communication
Allows the TeSys U starter to be connected to
the network using the Advantsys STB protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply
LULC15 218.00
CANopen
Communication
Allows the TeSys U starter to be connected to
the network using the Can Open protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply
LULC08 218.00
Beckoff Communication
Allows the TeSys Ustarter to be connected to
the network using the Beckoff protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply
LULC14 218.00
Profibus Communication
Allows the TeSys Ustarter to be connected to
the network using the Profibus protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply
LULC07 218.00
DeviceNet
®
Communication
Allows the TeSys U starter to be connected to
the network using the Device Net protocol
Advanced or multi-function
control units (24 Vdc only)
and LU9BN11L or LU9MRL
pre-wired connector
Requires separate 24 Vdc
power supply
LULC09 218.00
p Communication capabilities can be integrated into existing automation architecture via a variety of protocols.
q See 18-29 for placement on the power base.
Table 18.120: Control Circuit Accessories f
Accessory Application Technical Data Mounting
Catalog
Number
$ Price
Control circuit contact block
Switches control circuit power via LUB
handle
(NEC430-74 compliance)
5 amp at 600 Vac
5 amp at 250 Vdc
Side mounting to LUB
and LU2B only
LUA8E20 71.00
Through-the-door operating
mechanism
Use in enclosures 7.5 to
20 inches deep. Use with LUB only.
——LU9AP00 125.00
Operating handle (NEMA 12) Use with LU9AP00
Black / Blue Enclosure door LU9AP11 31.50
Red / Yellow Enclosure door LU9AP12 31.50
Control circuit filters
Use with electronic or triac output
controllers
Up to 150 VAC max. Directly to coil terminals
Non-reversing LUA4F11 39.30
Reversing LUA4F12 39.30
r See page 29 for placement on the power base.
Table 18.121: PowerSuite Configuration Software and Accessories
Itema Catalog Number $ Priceb
PowerSuite software VW3A8104 225.00
PC connection kit VW3A8106 113.00
Pocket PC connection kit VW3A8111 143.00
a For complete details on all components included with each item, refer to Catalog #8502CT0201.
b Items under Discount Schedule CP4C.
Table 18.122: GV2 Cabling Accessories—Bus Bars
Description Application Pitch Standard Pack Catalog Number $ Price Each
3-Pole, 63 A Bus Bar
For feeding 2 GV2 starters or TeSys U
45
54
72
1
1
1
GV2G245
GV2G254
GV2G272
23.30
23.30
23.30
For feeding 3 GV2 starters or TeSys U
45 1 GV2G345 28.70
54 1 GV2G354 28.70
For feeding 4 GV2 starters or TeSys U
45
54
72
1
1
1
GV2G445
GV2G454
GV2G472
34.20
34.20
34.20
For feeding 5 GV2 starters or TeSys U 54 1 GV2G554 34.20
AS-Interface
Modbus
DeviceNet
Profibus
CANopen
I11
Discount
Schedule
er-style:none;position:absolute;left:431.380000px;bottom:193.960000px;width:71.640000px;height:0.000000px;background-color:rgba(255,255,255,0.000001);">
position:absolute;left:175.360000px;bottom:475.540000px;width:15.360000px;height:6.960000px;background-color:rgba(255,255,255,0.000001);">
Download

LP1K0910BD Documents

Schneider Electric
56 Pages / 5.46 MByte
Schneider Electric
16 Pages / 0.43 MByte
Schneider Electric
70 Pages / 3.42 MByte
Schneider Electric
26 Pages / 2.53 MByte

LP1K0910 Documents

Schneider Electric
TeSys K contactor - 3P, 3 NO, AC-3- 440V 9A - 24V DC coil
Schneider Electric
TeSys LP1K 3Pole Contactor, 9A, 4kW, 24V dc Coil
Schneider Electric
Schneider Electric Telemecanique - LP1K09103BD
Schneider Electric
Schneider Electric Telemecanique - LP1K0910GD
Schneider Electric
Schneider Electric Telemecanique - LP1K0910CD
Schneider Electric
Schneider Electric
Schneider Electric Telemecanique - LP1K0910UD
Schneider Electric
Schneider Electric Telemecanique - LP1K09103BD3
Schneider Electric
Schneider Electric Telemecanique - LP1K0910FD
Schneider Electric
Part Datasheet PDF Search
72,405,303 Parts Datasheet PDF, Update more than 5,000 PDF files ervery day.
Popular Datasheet