Part Datasheet Search > Signal Relays > Schneider Electric > LP1K0910BD Datasheet PDF > LP1K0910BD Datasheet Pages 34/56
LP1K0910BDDatasheet PDF
Page:
of 56 Go
If the format of the manual is confusing, please download and read the original PDF file.
www.schneider-electric.us
18
IEC CONTACTORS AND
STARTERS
18-34
© 2009 Schneider Electric
All Rights Reserved
Starters Accessories TeSys
®
GV2 and GV3 Manual Starters and Protectors
Refer to Catalog 2520CT0001
GVAU116
Table 18.128: Voltage Trips
Only one trip or fault signaling contact can be installed per GV2/GV3 device.
Description Characteristics Voltage Frequency Catalog Numbera $ Price
Voltage trips
GV2 & GV3P
Undervoltage or
Shunt trip
(external mount,
1 block right side only)
24 V
50 Hz GVA•025
81.00
60 Hz GVA•026
48 V
50 Hz GVA•055
60 Hz GVA•056
100–110 V 50/60 Hz GVA•107
110–115 V
50 Hz GVA
•115
60 Hz GVA
•116
120–127 V 50 Hz GVA•125
127 V 60 Hz GVA•115
200 V 50 Hz GVA•207
200–220 V 60 Hz GVA•207
220–240 V
50 Hz GVA•225
60 Hz GVA•226
380–400 V
50 Hz GVA•385
60 Hz GVA•386
415–440 V 50 Hz GVA•415
415 V 60 Hz GVA•416
440 V 60 Hz GVA•385
480 V 60 Hz GVA•415
500 V 50 Hz
GVA•505
600 V 60 Hz
a To order an under voltage trip: replace the bullet (•) with a U, example: GVAU025. To order a shunt trip: replace the bullet (•) with an S, example:
GVAS025.
GVAE11
GVAD0101
GVAN11
Table 18.129: Auxiliary Contact Blocks
Description
Mounting
Location
Max. No. of
Blocks
Contact Type Sold in lots of Catalog Number $ Price
Instantaneous auxiliary contacts
GV2 + GV3P
Frontbg 1
N.O. or N.C.c 1 GVAE1 21.80
N.O. + N.C. 10 GVAE11e 35.70
N.O. + N.O. 1 GVAE20e 35.70
Left Hand Side 2
N.O. + N.C. 1 GVAN11e 35.70
N.O. + N.O. 1 GVAN20e 35.70
Fault signaling contact +
instantaneous auxiliary contact
GV2 + GV3P
Left Hand Sided 1
N.O. (fault) + N.O. 1 GVAD1010 54.00
N.O. (fault) + N.C. 1 GVAD1001 54.00
N.C. (fault) + N.O. 1 GVAD0110 54.00
N.C. (fault) + N.C. 1 GVAD0101 54.00
Short circuit signaling contact
GV2 + GV3P
Left Hand Side 1 SPDT 1 GVAM11 35.70
b Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
c Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
d The GVAD is always mounted next to the starter.
e For spring terminals add 3 to the catalog number. Example: GVAE113
f One trip or one fault signaling can be fitted per GV3.
g Cannot be used with GV2GH7 insulator.
Table 18.130: Voltage Trips–Technical Data (GV2AU, GV2AS)
Rated Voltage–660 Vac
Model Inrush Sealed Pick-Up Voltage Drop-Out Voltage Operating Timeh
GVAU 12 VA / 8 W 3.5 VA / 1.1 W 0.8 to 1.1 0.35 to 0.7 10 to 15 ms
GVAS 14 VA / 10.5 W 5 VA / 1.6 W 0.7 to 1.1 0.2 to 0.75 10 to 15 ms
h From the loss of voltage at the trip terminals to the opening of the starter contacts.
Table 18.131: GV3P Accessories
Description For GV3P Catalog Number $ Price
Set of 3-pole 115 A busbars
(tap-offs: 2, pitch: 64 mm)
GV3P
•• GV3G264 25.00
Set of 3-pole 115 A busbars
(tap-offs: 3, pitch: 64 mm)
GV3P
•• GV3G364 45.00
Cover “Larger Spacing” UL 508 type E
(Only one cover required on supply side)
GV3P•• GV3G66 18.00
IP 20 cover
(Two covers required per starter)
GV3P
•• LAD96570 12.00
Padlocking device
For use with up to 4 padlocks (not supplied)
Ø 6 mm shank maximum
GV3P
••
GV3P•••
GV2V03 15.00
New!
CP10 I11
Discount
Schedule