description/ordering information
●The LT1004 micropower voltage reference is a two-terminal band-gap reference diode designed to provide high accuracy and excellent temperature characteristics at very low operating currents. Optimizing the key parameters in the design, processing, and testing of the device results in specifications previously attainable only with selected units.
●Initial Accuracy
● − ±4 mV for LT1004-1.2
● − ±20 mV for LT1004-2.5
●Micropower Operation
●Operates up to 20 mA
●Very Low Reference Impedance
●Applications:
● − Portable Meter Reference
● − Portable Test Instruments
● − Battery-Operated Systems
● − Current-Loop Instrumentation