The ABT126 bus buffer gates feature independent line drivers with 3-state outputs. Each output is disabled when the associated output-enable (OE) input is low.
●When VCC is between 0 and 2.1 V, the device is in the high-impedance state during power up or power down. However, to ensure the high-impedance state above 2.1 V, OE should be tied to GND through a pulldown resistor; the minimum value of the resistor is determined by the current-sourcing capability of the driver.
● Typical VOLP (Output Ground Bounce)
● <1 V at VCC = 5 V, TA = 25°C
● High-Impedance State During Power Up and Power Down
● High-Drive Outputs (32-mA IOH, 64-mA IOL)
● Ioff and Power-Up 3-State Support Hot Insertion
● Latch-Up Performance Exceeds 500 mA Per JESD 17
● ESD Protection Exceeds JESD 22
● 2000-V Human-Body Model (A114-A)
● 200-V Machine Model (A115-A)