The AC05 devices contain six independent inverters. These devices perform the Boolean function Y = A\\. The open-drain outputs require pullup resistors to perform correctly, and can be connected to other open-drain outputs to implement active-low wired-OR or active-high wired-AND functions.
● AC Types Feature 1.5-V to 5.5-V Operation and Balanced Noise Immunity at 30% of the Supply Voltage
● Speed of Bipolar F, AS, and S, With Significantly Reduced Power Consumption
● Balanced Propagation Delays
● ±24-mA Output Drive Current
● Fanout to 15 F Devices
● SCR-Latchup-Resistant CMOS Process and Circuit Design
● Exceeds 2-kV ESD Protection Per MIL-STD-883, Method 3015