description/ordering information
●The ’AHC05 devices contain six independent inverters. These devices perform the Boolean function Y = A.
●The open-drain outputs require pullup resistors to perform correctly. They can be connected to other open-drain outputs to implement active-low wired-OR or active-high wired-AND functions.
●• Operating Range 2-V to 5.5-V VCC
●• Latch-Up Performance Exceeds 250 mA Per JESD 17
●• ESD Protection Exceeds JESD 22
● – 2000-V Human-Body Model (A114-A)
● – 200-V Machine Model (A115-A)
● – 1000-V Charged-Device Model (C101)