Specification
4060 Watts
• Low Cost
• Small Size
• Universal Input
• Rugged Design
• High MTBF
• International Safety Approvals
• Covered Versions Available
ACS Series
Input
Input Voltage • 90-264 VAC (110-370 VDC)
Input Frequency • 47-63 Hz
Input Current • ACS40: 0.45 A rms at 230 VAC
ACS60: 0.60 A rms at 230 VAC
Inrush Current • Cold start at 25 şC: 25 A at 115 VAC,
50 A at 230 VAC
Earthing • Class I
Output
Output Voltage • See table
Hold Up Time • 8 ms typical at full load
Line Regulation • 0.5%max at full load
Load Regulation • 1.0% max at 10% load to full load
Ripple & Noise • 1% max pk-pk, 20MHz BW
Overvoltage Protection • Typically 130% of max output
Overcurrrent Protection • 120% typical
xppower.com
General
Efficiency • See tables
Isolation • 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Switching Frequency • 50-70 kHz
MTBF • 230 kHrs per MIL-HDBK-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate from full load at
+50 °C to half load at +60 °C.
Reduce both temperatures by 10 °C when
cover is fitted
Storage Temperature • -40 °C to +85 °C
EMC & Safety
Emissions • FCC20780 Level B, CISPR22 (EN55022),
level B conducted
ESD Immunity • EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity • EN61000-4-3, 10 V/m Perf Criteria A
EFT/Burst • EN61000-4-4, level 2 Perf Criteria A
Surge • EN61000-4-5, level 3 Perf Criteria A
Conducted Immunity • EN61000-4-6, 10 V Perf Criteria y
Safety Approvals • EN60950, UL1950, CSA22.2 No. 234